LSA6
Leakage collection reservoir

LSA6
Leakage collection reservoir

LSA6 <br/>Leakage collection reservoir
LSA6000A4

A From mechanical seal
B To leakage collection system

LSA6
Leakage collection reservoir

Features

The EagleBurgmann leakage control systems of the LSA6000 range in accordance with API Plan 65A consist of a leakage collection tank with integrated orifice and overflow pipe. The level can be monitored with the differential pressure transmitter which is supplied together with a five-way manifold valve.

Advantages

  • Seal failure detection
  • Safe discarding of excessive seal leakage
  • To ensure durability, all components are corrosion resistant.

Standards and approvals

  • API 682 / ISO 21049
  • API 682 4th ed. Cat. 2/3 - 1CW-FL
  • API 682 4th ed. Cat. 1 - 1CW-FX

Functional description

In accordance with API Plan 65A, the LSA6000 leakage control system is used to discharge leakage from single seals. The outboard leakage is collected in an external tank; the leakage volume is monitored (level in the tank).

Notes

Design and production in accordance with EU Pressure Equipment Directive PED 2014/68/EU available.
Design, calculation and production available acc. to ASME VIII, Div. 1.

3rd party inspection, ASME stamp on request.

Recommended piping plans




Product variants

Designation LSA6000A4
Design code PED 2014/68/EU | ASME VIII, Div. 1
Volume of vessel (liters) 4
Allowable pressure1) 44 bar (638 PSI)
Allowable temperature1) -20 °C … +120 °C
(-4 °F … +248 °F)
Process connections Flange 3/4", 600 lbs
Metal parts 316/316L


Other versions on request.

1) Design data, permissible working values depend on the actual conditions of service.

Similar products

LSB6 Leakage collection reservoir

In accordance with API Plan 65B, the EagleBurgmann leakage control systems of the LSB6000 range consist of a leakage collection tank with valve and overflow pipe. The level can be monitored with the differential pressure transmitter which is supplied together with a five-way manifold valve.

LSC6 Leakage collection reservoir

The EagleBurgmann leakage control systems of the LSC6000A4 range are utilized to collect condensing or mixed phase leakage - vapor passing through. A level indicator is installed to determine when the tank needs to be drained. A pressure gauge tracks and indicates seal leakage.

SPP6 Leakage detection system

The EagleBurgmann leakage control systems of the SPP6006A4 range consist of a pressure transmitter which is supplied together with a block and bleed valve as well as an orifice and drain valve.
Contact

Inquire about individual solutions

We develop and produce customer-specific special and individual solutions for every application.

Inquire now Discover reference projects
Back to the overview